Maison

>

NJPL-330C Remplisseuse automatique de gélules liquides

Machine de remplissage automatique de capsules liquides NJPL-330C
Liquid Capsule Sample
Fiber Optic Detection
Servo Ceramic Pump Filling
Air Drying System
Machine de remplissage automatique de capsules liquides NJPL-330C
Liquid Capsule Sample
Fiber Optic Detection
Servo Ceramic Pump Filling
Air Drying System

NJPL-330C Remplisseuse automatique de gélules liquides

La machine de remplissage automatique de capsules liquides NJPL-330C remplit et scelle les huiles, suspensions, pastes, et solutions visqueuses dans des capsules dures (sizes 00#–3#), ensuring ±1–2% dosing accuracy and zero leakage.

Ideal for cGMP-compliant production, the NJPL-330C processes up to 18,000 capsules/hour with its patented turntable sealing technology and Schneider servo motors. Its modular design allows quick mold changes (15 minutes) and supports gelatin, HPMC, or plant-based capsules, catering to diverse regulatory and sustainability needs.

Enhanced by real-time quality control—automated rejection of misaligned capsule caps and ceramic pumps to handle sticky materials—the NJPL-330C guarantees 99.8% operational reliability. CE/cGMP/ISO-certified and backed by global technical support, it streamlines scalability for labs and large-scale facilities alike.

Spécification:

Jusqu'à 18,000 pièces/h

Livraison rapide en 15 jours

Convient pour les liquides, les granulés et les pastilles

How is the liquid capsule filler working?

Liquid encapsulation machine precisely doses viscous liquids into pre-opened capsule halves via servo-driven ceramic pumps, aligns both halves under controlled pressure, and hermetically seals them using patented thermal bonding technology to ensure leak-proof encapsulation.

Caractéristiques principales

Capacité de production18,000 pièces/h
En vigueurLiquide, granulé, pastille
Taille de la capsule#000-3
Pouvoir380/220 50Hz(customizable)
Bruit<65 dBA

Oil Capsule Filler Advantages

A Schneider servo motor and Japanese ceramic pump precisely control high-viscosity liquids (0.5–3,000 cP), ensuring zero active ingredient waste.

Fiber optic inspection eliminates misaligned caps and empty capsules in real time, achieving a yield rate of ≥99.8%.

A modular mold design allows for rapid switching between gelatin, HPMC, pullulan, and plant-based capsules (tailles 00#-3#) in under 15 minutes.

Principaux partis

How the NJPL-330C Achieves Pharmaceutical-Grade ±1-2% Liquid Filling Accuracy Under cGMP

In pharmaceutical and nutraceutical manufacturing, dosage accuracy isn’t just a metric—it’s a regulatory imperative. GMPc (current Good Manufacturing Practice) guidelines enforced by the FDA, EMA, and ICH mandate strict uniformity in drug products. Per USP General Chapter <905> “Uniformity of Dosage Units,” oral solid dosage forms must achieve acceptance values (AV) ≤15.0—translating to ≤5% variability for critical APIs. For high-potency drugs (hormones, cytotoxins), deviations beyond ±2% risk therapeutic failure or toxicity, making precision machinery non-negotiable.

The automatic capsule filling machine for liquid meets—and exceeds—these standards through a synchronized electro-mechanical system engineered for zero-compromise accuracy:

1. cGMP’s Precision Mandate: Why ±1-2% Matters

Temperature-sensitive biologics (peptides, live probiotics) degrade with overfilling.

Underfilled lipid-based drugs (isotretinoin) compromise bioavailability.

±2% tolerance ensures batch-to-batch consistency, eliminating QA rejections per 21 CFR 211.110.

2. The Core Precision Triad: Ceramic Pumps + Dual Servo Synergy

Japan Yaskawa Ceramic Dosing Pumps

Engineered with 0.1-µm surface roughness (contre. stainless steel’s 1.5µm) to prevent material adhesion.

Chemically inert zirconia construction resists corrosion from acids/alkalis (pH 1–14).

Maintains viscosity stability for shear-sensitive fluids (0.5–3,000 cP).

Dual Schneider Electric Lexium 32 Servo Motors

Motor A (Fill Control)

Governs piston displacement with 0.001mm resolution, digitally adjusting volume per capsule weight feedback.

Compensates for density changes in suspensions (40% solid-content probiotics).

Motor B (Anti-Drip & Retraction)

Executes 5ms reverse suction post-fill, creating negative pressure to retract droplets.

Prevents cross-contamination and capsule seal failure from residual liquid.

Environmental Stability Assurance

Temperature-controlled filling zone (±0.5°C) prevents thermal expansion/contraction of liquids.

Vibration-dampened mounts isolate pumps from machine oscillations.

Industry Impact: From Compliance to Competitive Edge

A major EU nutraceutical manufacturer reduced liquid capsule batch rejections from 12% à 0.3% after adopting the NJPL-330C—saving €380,000/year in wasted APIs. For injectable-grade fish oil encapsulation, ±1.5% accuracy enabled ICH Q3D elemental impurity compliance without over-engineering formulations.

Precision isn’t a luxury—it’s the bedrock of patient safety. The NJPL-330C’s servo-ceramic architecture sets the new GMP benchmark.— Dr. Elena Vogt, Pharmaceutical Manufacturing Consultant

Certified Precision: Validated per ASTM E2709/E2810 standards with 3x consecutive 0.98% RSD (Relative Standard Deviation).

Key Takeaways for Quality Directors

Regulatory Defense: Full electronic records (ERP integration) satisfy FDA 21 Partie CFR 11.

Cost Control: ±1% accuracy = 7–9% API savings vs. volumetric fillers.

Zero Contamination: Anti-drip servos reduce cleaning validations by 30%.

 

Ruidapacking also offers complete back-end packaging solutions. Par exemple, for packaging liquid capsules into aluminum-plastic blisters, machines d'emballage sous blister can meet your packaging needs. From the DPP-90R to the DPH-270Max, we offer a wide range of models, covering small, medium, and large production volumes. For packaging liquid capsules into bottles, a multi-capsule bottling line is the best choice. With 60 capsules per bottle as the standard, the RD-SLL-16H can produce up to 100 bottles per minute. Back-end cartoners, case packers, and palletizers are also available.

The Critical Role of Hermetic Sealing in Liquid Capsules: Why Precision Matters from Production to Patient

In liquid capsule manufacturing, the sealing process isn’t merely a final step—it’s the last line of defense against product failure, regulatory non-compliance, and brand erosion. A compromised seal can trigger catastrophic chain reactions: des fuites de principes actifs contaminent les lignes de conditionnement, perturber la logistique, et finalement livrer des produits inefficaces ou dangereux aux consommateurs. Voici comment le système d'étanchéité technique du NJPL-330C élimine ces risques.

1. Le coût élevé de la défaillance des joints: Trois étapes du désastre

Scène 1: Stockage & Effondrement de la durée de conservation

L'oxygène qui fuit pénètre dans les capsules non scellées, composés sensibles oxydants (par ex., huiles de poisson, vitamine E). Des études montrent qu'un micro-espace de 0,1 mm accélère la dégradation de l'API en 300% dans 3 mois.

Scène 2: Contamination des lignes d'emballage

Résidus collants provenant des fuites de capsules dans des machines à blister, forcer des nettoyages de 2 à 4 heures. Les usines pharmaceutiques signalent des pertes de 18 000 €/heure dues à des temps d'arrêt imprévus.

Scène 3: Transport & Dommages à la marque

Les vibrations pendant le transport élargissent les défauts microscopiques des joints, provoquant des fuites à l'échelle de la boîte. Les retours clients explosent 23% pour les produits avec >0.5% taux de défauts (Base de données des rappels de la FDA, 2024).

2. Technologie de roue à double joint: Conçu avec précision pour la chimie des capsules

Le NJPL-330C déploie une architecture d'étanchéité spécifique au matériau inégalée par les systèmes génériques à roue unique:

Type de capsuleMécanisme d'étanchéitéAvantage fondé sur la science
Gélatine animaleRoue simple chauffante (70–90°C)Activation optimisée de l'humidité: 5% la teneur en eau crée des liaisons covalentes irréversibles
HPMC/à base de plantesRoues jumelées (T1: 110°C, T2: 85°C)L'étape 1 fait fondre les chaînes de polymère HPMC; Interfaces de fusibles à pression étape 2 (100 N/cm²)

Pourquoi les concurrents échouent: Les soudeuses à roue unique surchauffent les capsules végétales (>120°C), provoquant une caramélisation et une fragilité.

3. Perfection après scellement: Le système de couteau à air DryGuard

L'humidité après le scellement est l'ennemi caché. Humidité résiduelle (≥8%) affaiblit les liaisons pendant le durcissement. Notre solution:

Flux d'air laminaire directionnel (Classe ISO 5 standard) accélère l’évaporation sans contamination par la poussière.

Des capteurs d'humidité de précision maintiennent l'humidité de la paroi de la capsule à 4,5 ± 0,5 %, le point de consigne idéal pour la cristallisation HPMC/gélatine..

30-le deuxième cycle de séchage garantit que les capsules entrent dans l'emballage avec Rockwell 80 dureté (contre. moyenne du secteur. 65).

4. Performances validées: Anti-fuite par conception

Tests tiers selon la Pharmacopée européenne 2.9.20 (Test d'étanchéité aux liquides):

Défi du vide: Les capsules résistent -0.9 barre pour 30 min (simulation de fret aérien).

Essai de compression: 50Force N appliquée aux joints scellés – zéro rupture à 40 °C/75 % HR.

Validation dans le monde réel: 0.002% taux de fuite dans les études de stabilité sur 12 mois (contre. limite cGMP de 0.1%).

Étude de cas: Sauver une marque de probiotiques du rappel

Une entreprise nutraceutique espagnole utilisant des scelleuses à roue unique 11% retours liés aux fuites. Après le passage au NJPL-330C:

Les défaillances d’intégrité des joints ont chuté à 0.03%;

Temps d'arrêt fulgurant de la machine réduit de 92%;

Les réclamations clients ont diminué de 240 000 €/an.

“Sceller ne consiste pas à coller deux moitiés ensemble, mais à créer une forteresse moléculaire. Le système à double roue de Ruidapacking est la seule solution de qualité GMP pour les formulations sensibles aux fuites.” — Dr. Simon Lefebvre, Directeur Emballage, Laboratoires EuroCaps.

Pourquoi c'est important pour votre entreprise

Protéger les investissements API: 1 fuite = 150 € de perte pour les médicaments très puissants (selon l'analyse ISPE);

Réduisez les coûts d’emballage: Zéro résidu liquide = 100% efficacité de la ligne blister;

Bâtir la confiance dans la marque: 99.97% taux de réussite des scellements → Utilisation des avis du NJPL-330C.

Demander un devis

    *Nous respectons votre confidentialité et toutes les informations sont protégées.